Eurofase Dimmable Smart Wi-Fi Heater Controller | EFIKWSMD
Eurofase Dimmable Smart Wi-Fi Heater Controller | EFIKWSMD
Available to order — ships from incoming stock
Typically ships in 3–6 Business Days (Western Canada) · 4–8 Business Days (Eastern Canada)
SKU:EFIKWSMD
MPN: EFIKWSMD
Eurofase EFIKWSMD is the manufacturer's separate, Canadian-origin Dimmable Smart Wi-Fi Controller for professionally specified electric infrared patio-heating systems. With app-based switching, adjustable heat output, timer functions and optional Alexa / Google Home voice control, this 2026 dimmable model offers a different load-control approach from the compact standard EFIKWSM. Confirm that the actual connected heater is approved for its selected dimming and wiring mode.
EFIKWSMD verified 2026 manufacturer specifications
| Exact model / manufacturer family | EFIKWSMD — Dimmable Smart Wi-Fi Controller |
|---|---|
| Supply | 120, 208 or 240 V AC / 60 Hz |
| Maximum resistive current | 30 A per model-specific 2026 specification and installation manual |
| Maximum stated load at 240 V | 7,200 W (30 A resistive load) — maximum rating, not an automatic approval for multiple heaters |
| Electrical output capabilities | Manufacturer describes relay on/off and solid-state voltage-regulation / dimming configurations; follow the exact approved heater and controller wiring diagram |
| Connected controls | Eurofase Heating mobile app, Wi-Fi and Bluetooth with 2.4-GHz wireless radio |
| App functions | On/off, adjustable heat/dimming, timer, multi-device management, voice-control integration via Alexa or Google Home |
| Automatic shut-off | 3 hours, per July 2026 model-specific specification |
| Enclosure / weather suitability | NEMA Type 3R surface-mount enclosure, for manufacturer-approved indoor/outdoor locations |
| Colour | Light grey |
| Controller dimensions | 11.5 in high × 10 in long × 4.75 in deep |
| Unit weight | Approximately 4 lb; manufacturer technical manual lists approximately 6 lb shipping weight |
| Manufacturer-recommended orientation | Vertical mounting on a heat-tolerant surface; do not hermetically enclose |
| Conductor notes | Copper conductors and manufacturer-specified terminal requirements; the installer must follow the specific electrical drawings |
| Origin / limited warranty | Canada / 3 years per Eurofase documentation |
Understand the differences between EFIKWSM and EFIKWSMD
| Selection factor | EFIKWSMD dimmable | EFIKWSM standard |
|---|---|---|
| Primary adjustment | Manufacturer-described output dimming plus on/off | On/off and HI/LO for approved dual-element heaters |
| Maximum published load | 30 A / 7,200 W at 240 V (2026 manuals) | Conflicting 30 A 2024 sheet and 32 A later manual; check actual model revision |
| Enclosure | NEMA Type 3R, approx. 11.5 × 10 × 4.75 in | IP65 per 2024 sheet, approx. 9.5 × 4.72 × 2.98 in |
| Manufacturer shut-off | 3-hour timer in 2026 sheet | Conflicting 3h website vs 4h spec/manual |
Compatibility is determined by the wiring—not just the 30 A rating
Eurofase publishes model-specific wiring illustrations for 120 V, 208 V and 240 V connections and single/dual heater-element arrangements. These drawings require interpretation for the actual heater and site; the catalogue does not authorize an arbitrary mix of EF40, EF60, LP40 or third-party resistive loads. A 6,000 W EF60 heater is nominally 25 A at 240 V, but that arithmetic alone does not establish dimming compatibility or that two heaters may share the same control output. Eurofase's app can manage multiple devices; this is not proof that one enclosure can carry multiple heater loads simultaneously.
Canadian installation and safety
Eurofase's EFIKWSMD installation manual requires installation by a licensed electrician, fixed wiring suitable for the Canadian Electrical Code, approved protective conduit, an accessible means of isolation, a heat-resistant vertical mounting surface and compliance with the device rating plate. Do not mount the controller close to a shower, bathtub or swimming pool, or where a user could touch the controls from water. Confirm the NEMA Type 3R mounting location is appropriate for the exposure and installation method.
Do not treat the 30 A specification as overcurrent-protection selection advice. Branch-circuit design, terminal capacities, conductor sizes and associated switching equipment must be verified from the final approved drawing and applicable code.
What is included
This listing is one EFIKWSMD dimmable controller. The manufacturer manual describes the controller and an installation guide; separate heater hardware, wall switching, disconnect equipment, wiring, mounting labour and any special freight are outside this listing unless separately contracted.
Verified manufacturer documentation
- Eurofase EFIKWSMD July 2026 model-specific specification (PDF) — actual device image, 30 A limit, 3-hour shut-off and dimensions
- Eurofase 2026 dimmable controller installation and wiring manual (PDF) — full electrical, mounting, connection, control and app-setup guidance
- Eurofase current heating document library
Questions dealers ask
Can this dim two 6,000 W EF60 heaters? Not directly on the basis of the 30 A controller rating. The combined 50 A nominal load exceeds that limit; any multi-heater architecture must use manufacturer-approved separate control equipment and circuitry.
Does a 3-hour auto shut-off mean it can run unattended? No. The timer is a safety feature, not an authorization to disregard installation and operating precautions.
Will it work with an existing EFIKWSM installation? Do not assume direct interchangeability; housing, output stage, electrical connections and current limits differ. The licensed installer must design any substitution.
Pre-order information: provide heater model, voltage, element configuration, quantity, independent zones and project wiring plan. Confirm current distributor availability, approved dimming architecture and final pricing before placing an order.
Warranty & Manuals
Warranty & Manuals
Spec / Sell Sheets
Spec / Sell Sheets
Share