EcoNet Bulldog automatic water-shutoff device; leak sensors and battery backup are not pictured

EcoNet Bulldog Dealer Kits: Planning Six vs Nine Leak Sensors

Automatic water-shutoff projects are won or lost in the site survey. A dealer can buy a correctly listed sensor package and still leave important leak locations unmonitored if the plan was never mapped. The EcoNet Bulldog dealer kits offer two repeatable starting points: six sensors or nine sensors, each with a battery-backup accessory. The right choice follows the building's actual risk points and system compatibility.

For broader seasonal damage-prevention and operating guidance, see our existing EcoNet winter flood and leak-protection guide. This article focuses on sensor coverage, the native kit BOM and contractor commissioning, rather than re-explaining winter water risks.

What is in each package?

Dealer project kit Included shutoff/sensor package Backup accessory
SC-ECO-LEAK6-BACKUP 1 × EVC400-MW-SK6 (six-sensor configuration) 1 × BB3K
SC-ECO-LEAK9-BACKUP 1 × EVC400-MW-SK9 (nine-sensor configuration) 1 × BB3K

The package names and manufacturer component SKUs identify the configured sensor-count variants; the itemized native Shopify BOM contains the shutoff/sensor package and listed backup accessory. Check the latest individual product page before any firm quotation.

Plan sensor locations before picking six or nine

Walk the property and list plausible points where an early leak indication could reduce damage. Potential survey locations can include laundry equipment, water heaters, under-sink cabinets, plumbing connections, equipment rooms, under-slab or seasonal-risk areas and spaces where the building owner has experienced failures. Sensor placement should follow actual leak paths and the manufacturer's installation instructions, not an arbitrary rule such as 'one sensor per bathroom'.

Six-sensor approach

The six-sensor package is a reasonable quotation starting point when a verified walkthrough produces six clear monitoring locations and the specified hardware meets the site's communications and placement needs. Record each intended sensor position on the commissioning checklist. Do not assume six sensors cover an entire property merely because the floor plan appears small.

Nine-sensor approach

The nine-sensor package may suit a verified plan with more distinct monitored locations—such as additional utility spaces, multiple plumbing zones or separate floors. The extra specified count does not automatically improve shutoff performance; it can help only when sensors are correctly installed, connected and tested at meaningful leak points.

The shutoff valve and communication path come first

  1. Inspect the physical valve. Confirm the existing shutoff style, operating access, safe mounting method, required clearances and manufacturer-supported compatibility for the exact Bulldog device.
  2. Check communication requirements. Map power/network coverage and pairing method needed by the selected device, rather than assuming every sensor reliably communicates through the same building materials.
  3. Plan backup and power interruption behavior. Verify the specified BB3K accessory's supported role and installation directions; a battery accessory is not a promise of indefinite off-grid operation.
  4. Plan human override. Document how the authorized building owner or service provider will safely inspect, test, restore and operate water service when required.
  5. Confirm physical and digital commissioning. Pair all sensors, prove alarm delivery and verify the actual automatic shutoff response under an approved site test. Record any test exclusions.

Commissioning worksheet

A useful turnover sheet records the kit SKU, Bulldog model, valve photo, each sensor location, unique sensor identifier, installed power/backup method, pairing result, alarm/notification test, shutoff test, date, technician and customer orientation. The installer should explain maintenance, battery checks and how to handle intentional water shutdowns.

What is outside the kit?

Plumbing repair or replacement, extra site sensors, network changes, labour, protective enclosures, maintenance and third-party professional services are not presumed included. A sensing system is an added protection layer, not a substitute for building inspections, sound plumbing and current local code requirements.

Frequently asked questions

Should every house receive the nine-sensor kit?

No. Count the monitored locations after a site survey and use the supported hardware configuration that meets the design.

Does backup power eliminate the need to test the system?

No. Commission both the normal operating configuration and supported backup behavior under manufacturer-approved procedures.

Can the kit guarantee that no water damage will occur?

No. Detection location, communications, valve operation, maintenance and events beyond sensor coverage all affect real-world results.

Take the next step

Compare EcoNet Bulldog six- and nine-sensor kits and use the dealer quoting guide to confirm project BOM, exclusions, customer handover and current supplier availability.

Back to blog

Leave a comment

Please note, comments need to be approved before they are published.