1
/
of
1
PDK RKPBV2 Red Reader V2 Single Gang Keypad High-Security Reader | RKPBV2
PDK RKPBV2 Red Reader V2 Single Gang Keypad High-Security Reader | RKPBV2
Available to order — ships from incoming stock
Typically ships in 3–7 Business Days (Western Canada) · 3–7 Business Days (Eastern Canada)
SKU:RKPBV2
Shipping terms (Free over $300) calculated at checkout.
Dealer summary: The PDK RKPBV2 Red Reader V2 Single Gang Keypad High-Security Reader is the single-gang keypad reader member of the new PDK Red Readers V2 line. It delivers OSDP and Wiegand output, a 2 in read range, IP65 weather resistance, and a cleaner install format for modern PDK Red deployments.
Best fit: Standard single-gang openings that need a larger reader body and onboard keypad support for PIN, card-or-PIN, or card-and-PIN deployments.
Key dealer specs
- Part number: RKPBV2
- Bluetooth BLE, 125 kHz prox, and 13.56 MHz high-security credential support plus onboard PIN entry.
- Output: OSDP or Wiegand; OSDP multi-drop can reduce homeruns on multi-reader projects.
- Power: 5-24VDC; max draw is 141 mA at 12VDC.
- Environmental range: -31 to 150 F / -35 to 66 C, up to 95% humidity, with IP65 protection.
- Dimensions: 5.25" x 3.29" x 0.92".
- Credential security: MIFARE DESFire EV2 / EV3 high-security support.
Installation and commissioning notes
- Max cable length guidance: 500 ft on Wiegand with 18 AWG, or 1000 ft on OSDP RS485 at 12VDC with 22 AWG shielded twisted pair.
- Power-up sequences help verify comm mode: Wiegand-only = red blink once, OSDP-only = green blink twice, Auto-Detect = green blink four times.
- Keypad models support local keypad format setup within 1 minute of reset for 4-bit, 8-bit, and 26-bit keypad formats.
- UL-listed 5-24VDC access control panel required. Wire colors and termination guidance are published in the official install guide.
Dealer verification checklist
- Confirm controller compatibility and whether the job should be wired in OSDP or Wiegand.
- Validate mounting surface and footprint for the selected single-gang keypad reader form factor.
- Confirm whether the opening needs credential-only operation or PIN capability.
- For high-security deployments, align reader choice with Red credentials and controller strategy.