{"product_id":"st-156006-simplytest-signaltek-ct-cable-certifier-cat6a-tia-568-touchscreen","title":"SimplyTEST SignalTEK CT Cable Certifier with Touchscreen — Cat5e to Cat6A TIA-568 | ST-156006","description":"\u003ch2\u003eSimplyTEST SignalTEK CT Cable Certifier with Touchscreen — ST-156006\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eST-156006 SignalTEK CT\u003c\/strong\u003e is a professional touchscreen cable certifier for Cat5e, Cat6, Cat6A, and Cat7 structured cabling — meeting ANSI\/TIA 568.2-D certification requirements on Canadian commercial, institutional, and government projects. It delivers TIA-568 pass\/fail certification reports that satisfy project specifications, building owners, and warranty registration requirements — at a significantly lower cost than comparable Fluke Networks instruments.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Canadian Contractors Are Switching to SignalTEK\u003c\/h3\u003e\n\u003cp\u003eTIA-568 cable certification is mandatory on federal, provincial, healthcare, and most institutional projects in Canada. Historically, the only practical options were Fluke DSX instruments at $15,000–25,000 CAD. The SignalTEK CT delivers ANSI\/TIA-568 compliant certification at a fraction of the price — making dedicated certification tools accessible to independent contractors and smaller cabling companies who previously had to rent or subcontract certification work.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etouchscreen interface\u003c\/strong\u003e allows intuitive test navigation and report generation in the field. Test results store directly on the unit and can be exported to professional PDF certification reports for client handover documentation.\u003c\/p\u003e\n\n\u003ch3\u003eKit Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × SignalTEK CT display unit with touchscreen\u003c\/li\u003e\n\u003cli\u003e1 × SignalTEK CT remote unit\u003c\/li\u003e\n\u003cli\u003e2 × Power modules\u003c\/li\u003e\n\u003cli\u003eRJ45 adapters\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eST-156006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplyTEST (SimplyBRANDS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat5e, Cat6, Cat6A, Cat7 UTP\/STP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI\/TIA 568.2-D, ISO\/IEC 11801 Class E\/Ea\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire map, length, insertion loss, NEXT, PSNEXT, ACR-F, PSACR-F, return loss, propagation delay, delay skew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTouchscreen display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReport Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePDF certification report export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e810093721306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 lbs \/ 7.85 kg (kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHTS Code (Canada)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9030.40.0000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSignalTEK CT vs SignalTEK NT — Which Certifier Do You Need?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eST-156006 SignalTEK CT\u003c\/strong\u003e certifies Cat5e through Cat6A — covering 99% of Canadian commercial structured cabling installed today. The \u003cstrong\u003eST-156005 SignalTEK NT\u003c\/strong\u003e adds Cat7 and Cat7A testing (Class F\/FA) for data centres, healthcare, and projects where future-proof infrastructure is specified.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the SignalTEK CT produce reports accepted on Canadian federal government projects?\u003c\/strong\u003e\u003cbr\u003eThe ST-156006 produces ANSI\/TIA 568.2-D certification reports. Acceptance of specific test equipment on federal projects is at the authority of the project specification and engineer of record. Consult your project specifications for approved test equipment lists.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of SignalTEK CT over just using a verifier?\u003c\/strong\u003e\u003cbr\u003eA verifier (like the VDV II series) only confirms wire map — it does not measure bandwidth parameters like NEXT, insertion loss, or return loss. Only a certifier can produce a TIA-568 pass\/fail result that meets commercial project warranty requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs Sapphire Care Plan (extended warranty\/calibration service) available for the SignalTEK CT?\u003c\/strong\u003e\u003cbr\u003eYes. SimplyTEST Sapphire Care Plans (ST-SCP1YR, ST-SCP2YR, ST-SCP3YR) provide extended coverage. Contact SimplyControlled.ca for pricing.\u003c\/p\u003e","brand":"SimplyTEST","offers":[{"title":"Default Title","offer_id":45730329034943,"sku":"ST-156006","price":2671.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0410\/6262\/9541\/files\/ST-156006-1.jpg?v=1781549152","url":"https:\/\/www.simplycontrolled.ca\/products\/st-156006-simplytest-signaltek-ct-cable-certifier-cat6a-tia-568-touchscreen","provider":"Simply Controlled","version":"1.0","type":"link"}