{"product_id":"eurofase-smart-wifi-controller-efikwsm","title":"Eurofase Smart Wi-Fi Controller | EFIKWSM","description":"\u003cdiv class=\"sc-commerce-structure\"\u003e\n\u003cp\u003e\u003cstrong\u003eEurofase EFIKWSM is the standard Smart Wi-Fi Controller for manufacturer-approved Eurofase infrared patio-heating installations.\u003c\/strong\u003e It supports convenient remote on\/off switching, timer operation and \u003cstrong\u003eHI\/LO control where the heater has an approved dual-element wiring scheme\u003c\/strong\u003e. EFIKWSM is a \u003cstrong\u003edifferent SKU from the EFIKWSMD Dimmable Smart Wi-Fi Controller\u003c\/strong\u003e; this standard model is not a general-purpose continuously dimmable heater driver.\u003c\/p\u003e\n\u003ch3\u003eEFIKWSM original manufacturer specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eExact manufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eEFIKWSM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e120 \/ 208 \/ 240 V AC; verify the ordered unit's rating plate and supply arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum controller load — document revision warning\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e30 A\u003c\/strong\u003e in Eurofase's December 2024 specification; \u003cstrong\u003e32 A \/ 7,680 W at 240 V\u003c\/strong\u003e in a later installation manual. These are conflicting published figures, not interchangeable installation approvals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl method\u003c\/th\u003e\n\u003ctd\u003eEurofase smartphone app; Wi-Fi plus Bluetooth using 2.4-GHz wireless radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput modes\u003c\/th\u003e\n\u003ctd\u003eOn\/off; HI\/LO for compatible dual-element heater arrangements; timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off — document revision warning\u003c\/th\u003e\n\u003ctd\u003e4 hours in 2024 specification and later installation manual; manufacturer web page states 3 hours. Confirm current installed firmware\/controller revision.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController body dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 9.5 × 4.72 × 2.98 in overall; source documents use different axis labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eLight grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation orientation\u003c\/th\u003e\n\u003ctd\u003eSurface-mounted vertically on a heat-resistant support; do not enclose hermetically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure classification\u003c\/th\u003e\n\u003ctd\u003eIP65 per Eurofase 2024 model-specific specification; review physical model label and approved location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer warranty\u003c\/th\u003e\n\u003ctd\u003e3 years, under manufacturer's limited warranty terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical setting\u003c\/th\u003e\n\u003ctd\u003ePermanent, professionally installed residential or commercial patio heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhy the 30 A \/ 32 A specification discrepancy matters\u003c\/h3\u003e\n\u003cp\u003eTwo Eurofase documents for the same EFIKWSM name publish different maximum ratings. The supplier's December 2024 model-specific sheet states \u003cstrong\u003e30 A\u003c\/strong\u003e, while the later downloadable installation manual states \u003cstrong\u003e32 A\u003c\/strong\u003e. The final equipment nameplate, approved revision, wiring diagram, manufacturer confirmation and electrical-code sizing govern the design. \u003cstrong\u003eDo not size wiring, switchgear or an EF60 heater group using the higher number based solely on this page.\u003c\/strong\u003e This discrepancy should be resolved with Eurofase before a specific project quote or order.\u003c\/p\u003e\n\u003ch3\u003eApp-based controls and automatic shut-off\u003c\/h3\u003e\n\u003cp\u003eEurofase describes smartphone on\/off switching, scheduling\/timer functions, management of multiple units in its app, and staged element selection on compatible dual-element heaters. Managing multiple heating devices in a mobile app is \u003cstrong\u003enot\u003c\/strong\u003e the same as permission to connect multiple heater loads to one controller output. The automatic shut-off duration differs between Eurofase's published product webpage and installation documents; avoid promising a particular duration until the model revision and firmware are known.\u003c\/p\u003e\n\u003ch3\u003eCompatible heaters and electrical design\u003c\/h3\u003e\n\u003cp\u003eManufacturer-approved combinations depend on the heater model, connected elements, simultaneous current, control wiring and circuit layout. For example, a single \u003ca href=\"\/products\/eurofase-ef40-4000w-240v-dual-element-infrared-patio-heater\"\u003eEF40 240 V 4,000 W\u003c\/a\u003e load is approximately 16.7 A, whereas a single \u003ca href=\"\/products\/eurofase-ef60-6000w-240v-patio-heater\"\u003eEF60 240 V 6,000 W\u003c\/a\u003e load is approximately 25 A. A two-heater system must not be presumed to fit the EFIKWSM output rating. The \u003ca href=\"\/products\/eurofase-lp40-4000w-240v-low-profile-patio-heater\"\u003eLP40\u003c\/a\u003e is single-element; do not advertise EF40-style HI\/LO behaviour for it without a specific approved wiring arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation requires a licensed electrician\u003c\/strong\u003e using a permanent wiring connection, appropriate grounding, conductor and terminal ratings, protected conduits, accessible disconnect means and the full Eurofase model-specific electrical instructions. The manufacturer's manual calls for vertical mounting on a heat-resistant surface and disallows placement within reach of people in pools, showers and other wet areas. Confirm installation site, power, environmental protections and applicable CEC requirements.\u003c\/p\u003e\n\u003ch3\u003eStandard versus dimmable Wi-Fi control\u003c\/h3\u003e\n\u003cp\u003eChoose EFIKWSM for the approved manufacturer-native on\/off and dual-element HI\/LO path. For applications requiring variable heat output, compare the \u003ca href=\"\/products\/eurofase-dimmable-smart-wi-fi-heater-controller-efikwsmd\"\u003eEFIKWSMD Dimmable Smart Wi-Fi Controller\u003c\/a\u003e, which has its \u003cstrong\u003eown 2026 30 A resistive-load rating, different enclosure and separate installation manual\u003c\/strong\u003e. Do not substitute either controller without comparing exact heater compatibility, output configuration, supply, protections and the project design.\u003c\/p\u003e\n\u003ch3\u003eIncluded equipment and ordering scope\u003c\/h3\u003e\n\u003cp\u003eThe EFIKWSM installation guide describes the controller, instruction manual and rated connection hardware. The heater, installer-supplied disconnects and additional electrical material are not automatically included. Confirm package contents and current available controller revision at ordering.\u003c\/p\u003e\n\u003ch3\u003eOfficial Eurofase documents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/eurofaseheating.com\/wp-content\/uploads\/2025\/01\/EH-Spec-Sheet-Wifi-Bluetooth-box_12132024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEFIKWSM December 2024 model-specific specification (PDF)\u003c\/a\u003e — model identification, 30 A rating, IP65, dimensions, HI\/LO and 4-hour shut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/eurofaseheating.com\/wp-content\/uploads\/2025\/12\/EFH_WiFiController_IM_02-12192025.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEurofase EFIKWSM installation and technical manual (PDF)\u003c\/a\u003e — later 32 A specification, wiring, installation and app setup\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/eurofaseheating.com\/controls-smart-wifi-control\/\" target=\"_blank\" rel=\"noopener\"\u003eEurofase current standard Smart Wi-Fi controller page\u003c\/a\u003e — different stated shut-off duration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDealer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes EFIKWSM provide continuous dimming?\u003c\/strong\u003e No; this model's manufacturer descriptions specify on\/off and compatible staged HI\/LO control. Choose a suitably approved dimmable controller for proportional adjustment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to connect two EF60 heaters to one controller?\u003c\/strong\u003e Do not assume so. Each EF60 heater has a nominal 25 A load at 240 V; use an appropriate engineered system with manufacturer-verified circuit ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the maximum 30 A or 32 A?\u003c\/strong\u003e Both appear in original Eurofase documents. Determine the exact hardware revision and follow the actual rating plate and the manufacturer's instructions before specifying a system.\u003c\/p\u003e\n\u003cp\u003eAll final supply, freight and dealer pricing remain subject to confirmation prior to release.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Eurofase","offers":[{"title":"Default Title","offer_id":50486086500543,"sku":"EFIKWSM","price":363.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0410\/6262\/9541\/files\/eurofase-smart-wifi-controller-system.png?v=1790188856","url":"https:\/\/www.simplycontrolled.ca\/products\/eurofase-smart-wifi-controller-efikwsm","provider":"Simply Controlled","version":"1.0","type":"link"}