{"product_id":"eurofase-dimmable-smart-wi-fi-heater-controller-efikwsmd","title":"Eurofase Dimmable Smart Wi-Fi Heater Controller | EFIKWSMD","description":"\u003cdiv class=\"sc-commerce-structure\"\u003e\n\u003cp\u003e\u003cstrong\u003eEurofase EFIKWSMD is the manufacturer's separate, Canadian-origin Dimmable Smart Wi-Fi Controller for professionally specified electric infrared patio-heating systems.\u003c\/strong\u003e With app-based switching, adjustable heat output, timer functions and optional Alexa \/ Google Home voice control, this \u003cstrong\u003e2026 dimmable model\u003c\/strong\u003e offers a different load-control approach from the compact standard \u003ca href=\"\/products\/eurofase-smart-wifi-controller-efikwsm\"\u003eEFIKWSM\u003c\/a\u003e. Confirm that the actual connected heater is approved for its selected dimming and wiring mode.\u003c\/p\u003e\n\u003ch3\u003eEFIKWSMD verified 2026 manufacturer specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eExact model \/ manufacturer family\u003c\/th\u003e\n\u003ctd\u003eEFIKWSMD — Dimmable Smart Wi-Fi Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e120, 208 or 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum resistive current\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e30 A\u003c\/strong\u003e per model-specific 2026 specification and installation manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum stated load at 240 V\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e7,200 W (30 A resistive load)\u003c\/strong\u003e — maximum rating, not an automatic approval for multiple heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output capabilities\u003c\/th\u003e\n\u003ctd\u003eManufacturer describes relay on\/off and solid-state voltage-regulation \/ dimming configurations; follow the exact approved heater and controller wiring diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnected controls\u003c\/th\u003e\n\u003ctd\u003eEurofase Heating mobile app, Wi-Fi and Bluetooth with 2.4-GHz wireless radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApp functions\u003c\/th\u003e\n\u003ctd\u003eOn\/off, adjustable heat\/dimming, timer, multi-device management, voice-control integration via Alexa or Google Home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003e3 hours, per July 2026 model-specific specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure \/ weather suitability\u003c\/th\u003e\n\u003ctd\u003eNEMA Type 3R surface-mount enclosure, for manufacturer-approved indoor\/outdoor locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eColour\u003c\/th\u003e\n\u003ctd\u003eLight grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController dimensions\u003c\/th\u003e\n\u003ctd\u003e11.5 in high × 10 in long × 4.75 in deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 4 lb; manufacturer technical manual lists approximately 6 lb shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer-recommended orientation\u003c\/th\u003e\n\u003ctd\u003eVertical mounting on a heat-tolerant surface; do not hermetically enclose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductor notes\u003c\/th\u003e\n\u003ctd\u003eCopper conductors and manufacturer-specified terminal requirements; the installer must follow the specific electrical drawings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin \/ limited warranty\u003c\/th\u003e\n\u003ctd\u003eCanada \/ 3 years per Eurofase documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eUnderstand the differences between EFIKWSM and EFIKWSMD\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSelection factor\u003c\/th\u003e\n\u003cth\u003eEFIKWSMD dimmable\u003c\/th\u003e\n\u003cth\u003eEFIKWSM standard\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary adjustment\u003c\/td\u003e\n\u003ctd\u003eManufacturer-described output dimming plus on\/off\u003c\/td\u003e\n\u003ctd\u003eOn\/off and HI\/LO for approved dual-element heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum published load\u003c\/td\u003e\n\u003ctd\u003e30 A \/ 7,200 W at 240 V (2026 manuals)\u003c\/td\u003e\n\u003ctd\u003eConflicting 30 A 2024 sheet and 32 A later manual; check actual model revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R, approx. 11.5 × 10 × 4.75 in\u003c\/td\u003e\n\u003ctd\u003eIP65 per 2024 sheet, approx. 9.5 × 4.72 × 2.98 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer shut-off\u003c\/td\u003e\n\u003ctd\u003e3-hour timer in 2026 sheet\u003c\/td\u003e\n\u003ctd\u003eConflicting 3h website vs 4h spec\/manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility is determined by the wiring—not just the 30 A rating\u003c\/h3\u003e\n\u003cp\u003eEurofase publishes model-specific wiring illustrations for 120 V, 208 V and 240 V connections and single\/dual heater-element arrangements. These drawings require interpretation for the actual heater and site; the catalogue does \u003cstrong\u003enot\u003c\/strong\u003e authorize an arbitrary mix of EF40, EF60, LP40 or third-party resistive loads. A 6,000 W EF60 heater is nominally 25 A at 240 V, but that arithmetic alone does not establish dimming compatibility or that two heaters may share the same control output. Eurofase's app can manage multiple devices; \u003cstrong\u003ethis is not proof that one enclosure can carry multiple heater loads simultaneously\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCanadian installation and safety\u003c\/h3\u003e\n\u003cp\u003eEurofase's EFIKWSMD installation manual requires installation by a \u003cstrong\u003elicensed electrician\u003c\/strong\u003e, fixed wiring suitable for the Canadian Electrical Code, approved protective conduit, an accessible means of isolation, a heat-resistant vertical mounting surface and compliance with the device rating plate. Do not mount the controller close to a shower, bathtub or swimming pool, or where a user could touch the controls from water. Confirm the NEMA Type 3R mounting location is appropriate for the exposure and installation method.\u003c\/p\u003e\n\u003cp\u003eDo not treat the 30 A specification as overcurrent-protection selection advice. Branch-circuit design, terminal capacities, conductor sizes and associated switching equipment must be verified from the final approved drawing and applicable code.\u003c\/p\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cp\u003eThis listing is \u003cstrong\u003eone EFIKWSMD dimmable controller\u003c\/strong\u003e. The manufacturer manual describes the controller and an installation guide; separate heater hardware, wall switching, disconnect equipment, wiring, mounting labour and any special freight are outside this listing unless separately contracted.\u003c\/p\u003e\n\u003ch3\u003eVerified manufacturer documentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/eurofaseheating.com\/wp-content\/uploads\/2026\/09\/EH-Spec-Sheet-WiFi-Control-Box-Dimmable_07292026-5.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEurofase EFIKWSMD July 2026 model-specific specification (PDF)\u003c\/a\u003e — actual device image, 30 A limit, 3-hour shut-off and dimensions\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/eurofaseheating.com\/wp-content\/uploads\/2026\/09\/EFH_WiFiControllerDimmable_IM.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEurofase 2026 dimmable controller installation and wiring manual (PDF)\u003c\/a\u003e — full electrical, mounting, connection, control and app-setup guidance\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/eurofaseheating.com\/download\/\" target=\"_blank\" rel=\"noopener\"\u003eEurofase current heating document library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQuestions dealers ask\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this dim two 6,000 W EF60 heaters?\u003c\/strong\u003e Not directly on the basis of the 30 A controller rating. The combined 50 A nominal load exceeds that limit; any multi-heater architecture must use manufacturer-approved separate control equipment and circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a 3-hour auto shut-off mean it can run unattended?\u003c\/strong\u003e No. The timer is a safety feature, not an authorization to disregard installation and operating precautions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it work with an existing EFIKWSM installation?\u003c\/strong\u003e Do not assume direct interchangeability; housing, output stage, electrical connections and current limits differ. The licensed installer must design any substitution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePre-order information:\u003c\/strong\u003e provide heater model, voltage, element configuration, quantity, independent zones and project wiring plan. Confirm current distributor availability, approved dimming architecture and final pricing before placing an order.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Eurofase","offers":[{"title":"Default Title","offer_id":67769463046335,"sku":"EFIKWSMD","price":500.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0410\/6262\/9541\/files\/efikwsmd_v1_1k__58884.webp?v=1793051310","url":"https:\/\/www.simplycontrolled.ca\/products\/eurofase-dimmable-smart-wi-fi-heater-controller-efikwsmd","provider":"Simply Controlled","version":"1.0","type":"link"}