{"product_id":"alula-re214t","title":"Alula RE214T Wireless Smoke \u0026 Heat Alarm – 2GIG Compatible 345 MHz | RE214T","description":"\u003csection\u003e\n\u003ch2\u003eAlula RE214T Wireless Smoke \u0026amp; Heat Alarm – 2GIG Compatible 345 MHz\u003c\/h2\u003e\n\u003cp\u003eAdd dependable fire protection to a \u003cstrong\u003e2GIG-compatible 345 MHz\u003c\/strong\u003e wireless security system. The \u003cstrong\u003eAlula RE214T\u003c\/strong\u003e is a wireless \u003cstrong\u003esmoke and heat\u003c\/strong\u003e alarm designed to trigger when it detects smoke or when temperatures rise above \u003cstrong\u003e135°F (57°C)\u003c\/strong\u003e. It includes a loud \u003cstrong\u003ebuilt-in temporal-3 sounder\u003c\/strong\u003e and also transmits alarm and status signals to your panel.\u003c\/p\u003e\n\u003cp\u003eThis model is commonly used as a \u003cstrong\u003ereplacement option for 2GIG CO3-345\u003c\/strong\u003e within the same 345 MHz ecosystem. Always confirm panel compatibility before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e 2GIG compatible wireless ecosystem (\u003cstrong\u003e345 MHz\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement option:\u003c\/strong\u003e 2GIG CO3-345\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection:\u003c\/strong\u003e Photoelectric smoke + fixed heat + rate-of-rise elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat sensor:\u003c\/strong\u003e 135 ± 5°F (57 ± 2°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder:\u003c\/strong\u003e Built-in \u003cstrong\u003etemporal 3\u003c\/strong\u003e, \u003cstrong\u003e85 dBA\u003c\/strong\u003e @ 10 ft (3 m) minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke sensitivity:\u003c\/strong\u003e \u003cstrong\u003e1.95% to 4% OBS\/ft\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries (replacement):\u003c\/strong\u003e 2 × Panasonic \u003cstrong\u003eCR123A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignals:\u003c\/strong\u003e Low battery, supervision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e FCC, IC, UL217, ULC 531\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 4.4°C to 37.8°C (40°F to 100°F), long term\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 15% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 4.7 × 1.8 in (12.0 × 4.6 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (with batteries):\u003c\/strong\u003e 7.36 oz (210 g)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5-year manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery replacement (quick note)\u003c\/h3\u003e\n\u003cp\u003eTo replace the batteries, detach the smoke alarm from its mounting plate and replace the batteries.\u003c\/p\u003e\n\u003ch3\u003eWhere to place a smoke alarm (practical guidance)\u003c\/h3\u003e\n\u003cp\u003eFollow the manual and local requirements. In general, install smoke alarms on each level and near sleeping areas, and avoid drafty locations near windows, doors, or supply vents that can affect detection.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eRE214T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWireless frequency\u003c\/th\u003e\n\u003ctd\u003e345 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSmoke sensing\u003c\/th\u003e\n\u003ctd\u003ePhotoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHeat sensing\u003c\/th\u003e\n\u003ctd\u003e135 ± 5°F (57 ± 2°C) + rate-of-rise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSounder\u003c\/th\u003e\n\u003ctd\u003eTemporal 3, 85 dBA @ 10 ft (3 m) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSmoke sensitivity\u003c\/th\u003e\n\u003ctd\u003e1.95% to 4% OBS\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBatteries (replacement)\u003c\/th\u003e\n\u003ctd\u003e2 × Panasonic CR123A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e4.4°C to 37.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e15% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eFCC, IC, UL217, ULC 531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e4.7 × 1.8 in (12.0 × 4.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWeight (with batteries)\u003c\/th\u003e\n\u003ctd\u003e7.36 oz (210 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/alula.com\/download\/re214t-smoke-alarm\/\" rel=\"noopener\" target=\"_blank\"\u003eAlula RE214T Smoke Alarm Manual (PDF)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eIs the RE214T compatible with 2GIG systems?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe RE214T is specified as \u003cstrong\u003e2GIG compatible\u003c\/strong\u003e and operates on \u003cstrong\u003e345 MHz\u003c\/strong\u003e. Confirm your panel supports 2GIG-style 345 MHz wireless devices before ordering.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat does temporal 3\" mean?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eTemporal-3 is a standardized alarm cadence used by many smoke alarms. The RE214T includes a built-in temporal-3 sounder for local alerting.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat batteries does it use?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe specifications list \u003cstrong\u003etwo Panasonic CR123A\u003c\/strong\u003e as replacement batteries. Replace batteries by detaching the alarm from its mounting plate.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size: 0.95em;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Always follow the included manual and any local fire safety requirements.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Alula","offers":[{"title":"Default Title","offer_id":45798430081215,"sku":"RE214T","price":107.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0410\/6262\/9541\/files\/IMG_9754.jpg?v=1782749463","url":"https:\/\/www.simplycontrolled.ca\/products\/alula-re214t","provider":"Simply Controlled","version":"1.0","type":"link"}