{"product_id":"alula-re214","title":"Alula RE214 Wireless Smoke + Heat Alarm (Honeywell Compatible, 345 MHz | RE214","description":"\u003csection\u003e\n\u003ch2\u003eAlula RE214 Wireless Smoke \u0026amp; Heat Alarm – Honeywell Compatible 345 MHz\u003c\/h2\u003e\n\u003cp\u003eAdd reliable fire protection to a Honeywell-compatible wireless security ecosystem. The \u003cstrong\u003eAlula RE214\u003c\/strong\u003e is a \u003cstrong\u003emulticriteria\u003c\/strong\u003e wireless smoke alarm that also alarms on heat, providing life-safety coverage for Canadian homes and monitored properties when smoke is detected or temperatures exceed \u003cstrong\u003e57°C (135°F)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe RE214 includes a loud \u003cstrong\u003e85 dBA\u003c\/strong\u003e built-in sounder (rated at \u003cstrong\u003e10 ft \/ 3 m\u003c\/strong\u003e minimum) and transmits key status signals such as \u003cstrong\u003elow battery\u003c\/strong\u003e and \u003cstrong\u003esupervision\u003c\/strong\u003e to the alarm panel.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Honeywell-compatible wireless ecosystem (\u003cstrong\u003e345 MHz\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm type:\u003c\/strong\u003e Multicriteria smoke alarm + heat alarm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat alarm threshold:\u003c\/strong\u003e alarms at temperatures above \u003cstrong\u003e57°C (135°F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in sounder:\u003c\/strong\u003e \u003cstrong\u003e85 dBA\u003c\/strong\u003e at 10 ft (3 m) minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke sensitivity:\u003c\/strong\u003e \u003cstrong\u003e1.82% to 2.92% OBS\/ft\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e replacement batteries listed as \u003cstrong\u003etwo Panasonic CR123A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel indications:\u003c\/strong\u003e Low battery, supervision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e FCC, IC, UL217 (8th edition), ULC-S531 (3rd edition)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 4.4°C to 37.8°C (40°F to 100°F), long term\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 15% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 4.7 × 1.8 in (12.0 × 4.6 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (with batteries):\u003c\/strong\u003e 7.36 oz (210 g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery replacement (quick note)\u003c\/h3\u003e\n\u003cp\u003eTo replace the batteries, detach the smoke alarm from its mounting plate and replace the batteries.\u003c\/p\u003e\n\u003ch3\u003eWhere to place a smoke alarm (practical guidance)\u003c\/h3\u003e\n\u003cp\u003eFollow the manual and local requirements. In general, install smoke alarms on each level and near sleeping areas, and avoid drafty locations near windows, doors, or supply vents that can affect detection.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eRE214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWireless frequency\u003c\/th\u003e\n\u003ctd\u003e345 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAlarm type\u003c\/th\u003e\n\u003ctd\u003eMulticriteria smoke + heat alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHeat alarm\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 57°C (135°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSounder\u003c\/th\u003e\n\u003ctd\u003e85 dBA @ 10 ft (3 m) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSmoke sensitivity\u003c\/th\u003e\n\u003ctd\u003e1.82% to 2.92% OBS\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBatteries (replacement)\u003c\/th\u003e\n\u003ctd\u003e2 × Panasonic CR123A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e4.4°C to 37.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e15% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eFCC, IC, UL217 8th, ULC-S531 3rd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e4.7 × 1.8 in (12.0 × 4.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWeight (with batteries)\u003c\/th\u003e\n\u003ctd\u003e7.36 oz (210 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/alula.com\/wp-content\/uploads\/2019\/12\/RE214_47-0023-02_RevB_Web.pdf\" rel=\"noopener\" target=\"_blank\"\u003eAlula RE214 User Manual (PDF)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eIs the RE214 compatible with Honeywell wireless systems?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe RE214 is specified as \u003cstrong\u003eHoneywell compatible\u003c\/strong\u003e and operates on \u003cstrong\u003e345 MHz\u003c\/strong\u003e. Confirm your system supports Honeywell-style 345 MHz wireless devices before ordering.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat does multicriteria smoke alarm” mean?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eMulticriteria” indicates the alarm uses more than one input\/decision method to improve performance. Always follow the manual for intended use, placement, and testing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat batteries does it use?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe specifications list \u003cstrong\u003etwo Panasonic CR123A\u003c\/strong\u003e as replacement batteries. Replace batteries by detaching the alarm from its mounting plate.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size: 0.95em;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Always follow the included manual and any local fire safety requirements.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Alula","offers":[{"title":"Default Title","offer_id":45798430146751,"sku":"RE214","price":107.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0410\/6262\/9541\/files\/IMG-9757.jpg?v=1782749464","url":"https:\/\/www.simplycontrolled.ca\/products\/alula-re214","provider":"Simply Controlled","version":"1.0","type":"link"}